Search this comparison and you will land on clinic blogs telling you pico is the “powerful” one and Moxi is the “starter version.” One med spa puts it exactly that way: Moxi “doesn’t quite have the same power.”
That framing is wrong, and it is expensive.
Moxi’s target is water. Pico’s target is melanin. A machine that heats water and a machine that shatters pigment are not competing on strength. They are doing different jobs in the same skin.
Here is what each one actually does, what US clinics charge for it, what the hardware costs to own, and which one to buy first.

Fig 1. Left: 1927 nm energy is absorbed by water and stops in the upper epidermis. Right: picosecond wavelengths reach pigment deeper in the dermis.
The 30-Second Answer
| The client’s problem | The right machine | Why |
|---|---|---|
| Diffuse dullness, uneven tone, early sun damage, maintenance | Moxi 1927 nm | Targets water. Renews the whole epidermal layer with near-zero downtime. |
| Discrete sun spots, freckles, tattoo, PMU, post-inflammatory pigment | Pico 755 / 1064 nm | Targets melanin. Shatters pigment mechanically. 1064 nm for deeper skin tones. |
| Acne scarring, enlarged pores, laxity | Neither | Needs fractional RF microneedling, CO₂, or an energy device that reaches the dermis. |
If you are a clinic owner, that table is also a purchasing decision. If 60% of your enquiries are “my skin looks tired,” you have a 1927 nm problem. If 60% are “I want this tattoo gone,” you have a pico problem. Buying the wrong one is a $1,300 to $200,000 mistake depending on which platform you sign for.
Why “Which Is Stronger” Is the Wrong Question
A laser only does one thing: it deposits energy into whatever chromophore absorbs its wavelength. Everything else — the marketing, the before/afters, the “level” language — follows from that single physical fact.
1927 nm is absorbed by water. Water is everywhere in the epidermis. So a 1927 nm fractional beam creates columns of controlled heat in the upper skin without needing melanin to be present. Sciton’s own protocol calls it a “gentle, non-ablative, fractionated wavelength.” Because it does not compete with melanin for absorption, clinicians call it “colour blind” — which is why it can be used on Fitzpatrick IV–VI with far less pigment risk than a melanin-targeting laser.
532 / 755 / 1064 nm are absorbed by melanin and haemoglobin. A picosecond pulse hits pigment so fast that the particle shatters mechanically instead of heating surrounding tissue. That is why pico clears ink and pigment in fewer sessions than a nanosecond Q-switched laser.
Two different chromophores. Two different mechanisms. Zero basis for ranking them by power.
| Wavelength | Absorbs into | What it is for | Typical downtime |
|---|---|---|---|
| 1927 nm | Water | Diffuse photodamage, tone, texture maintenance | 0–2 days (makeup after 24 h per Sciton); 5–7 days at high intensity |
| 532 nm | Melanin, haemoglobin | Epidermal pigment, red / orange / yellow ink | 1–3 days |
| 755 nm | Melanin (high absorption) | Blue and green ink, freckles, sun spots | 1–3 days |
| 1064 nm | Melanin (deeper, lower epidermal absorption) | Black and dark blue ink, dermal pigment, deeper skin tones | 1–2 days |
| 1320 nm | Water and carbon | Carbon peel, pores, texture | 1–2 days |
Read that table again with a client in front of you. Blue-green tattoo sleeve? 755 nm. Melasma on Fitzpatrick V? 1064 nm at low fluence, not 755. Dull skin with no discrete lesion? 1927 nm. The table answers the consultation faster than any brochure.
If you want the physics behind the 1927 nm band, we wrote it up separately: what a 1927 nm thulium laser actually does.
What Each One Actually Does to a Client
Moxi: the maintenance treatment
Sciton publishes the operational numbers: 8–10 minutes of treatment time, makeup after 24 hours (Sciton MOXI protocol). That is a lunch-break appointment, and it is the single most useful fact on this page for scheduling.
Intensity is not one setting. Clinics running Moxi describe three tiers — Level 1 with no numbing cream and no downtime for clients in their twenties; Level 3 requiring topical anaesthetic and 5–7 days of recovery, and only offered after a client has tolerated Level 2. The protocol most clinics quote is three sessions, four to six weeks apart, then maintenance every two to three months.
Results arrive in two waves. Brightening shows in one to two weeks as the treated columns shed. Collagen change takes four to six weeks.
What Moxi cannot do: tattoos, permanent makeup, deep dermal pigment, acne scars. It is a surface renewal tool, and Sciton markets it as prevention, not correction. (“Prejuvenation” is their word.)
Pico: the pigment and ink tool
Picosecond pulses work by photoacoustic effect. The pulse is shorter than the thermal relaxation time of the pigment particle, so the particle breaks apart instead of cooking the skin around it. Less collateral heat, less PIH risk than nanosecond systems, more complete clearance per session.
Wavelength count is the spec that decides your menu. A 532/1064 two-wavelength machine cannot clear green ink — those particles need 755 nm. If your intake includes colour work, PMU removal, or a mixed-ink population, a two-wavelength device will send clients home unfinished.
The 1320 nm band extends a pico platform into carbon peel: a repeatable, low-downtime facial that fills booking gaps between tattoo cases. Full spec on the 4-wavelength Z150Pro page.
What pico cannot do: whole-face epidermal renewal for diffuse photodamage. There is no 1927 nm water absorption in a 755/1064 system, so the “tired skin, no single spot” client is not a pico case. And 755 nm on Fitzpatrick IV–VI needs real caution — that is a PIH conversation, not a menu item.
For the ink side of the decision, the Q-switched vs pico comparison covers clearance rates and wavelength gaps.
What US Clinics Charge
Search results for this query are dominated by Singapore clinics quoting SGD 800 to SGD 1,200 per session. Useful for Singapore. Useless for a clinic in Ohio pricing a menu.
US market rates for 2026, based on published clinic pricing across metro and mid-size markets:
| Treatment | Per session | Series | Total |
|---|---|---|---|
| Moxi (full face) | $600–900 | 3–4 sessions, 4–6 weeks apart | $1,800–3,600 |
| Pico (face, pigment) | $300–800 | 3–6 sessions by indication | $900–4,800 |
| Pico (tattoo) | $200–500, sized by area | 6–12 sessions typical | Highly variable |
The gap is not a quality gap. It is a structure gap: Moxi is priced as a premium platform treatment with a short series; pico is priced per indication, and tattoo removal is a long series with small per-session tickets.
One pricing note worth stealing from the clinics that do it well: bundle the series. Package pricing runs 15–25% below per-session rates and locks the client into the full protocol, which is where the result actually comes from.
What the Machines Cost a Clinic
This is the part no page in the top ten answers. Every article tells you what the patient pays. Not one tells you what the clinic pays.
There are two hardware models, and they are not close.
Platform laser. Moxi runs on Sciton’s platform with a dedicated handpiece. Industry pricing for premium multi-application platforms of this class sits in the hundreds of thousands of dollars, plus handpiece and service contracts. That capital structure is why Moxi commands $600–900 a session — the clinic is amortising a platform, not a box.
Tabletop pico. A four-wavelength picosecond console — 532/755/1064/1320 nm, 1500 W, 2000 mJ per pulse, 5,000,000-shot source — lists at $1,250–1,300 per set from IVIVA LASER, with a two-year warranty and no per-treatment licensing. That is the entire capital outlay.
Cost per treatment, not cost per machine
Machine price means nothing until you divide it by the treatments it delivers.
A 5,000,000-shot source at roughly 800–1,500 shots per facial pigment case is 3,300 to 6,200 treatment cases before the source is spent. At $1,250 for the console, equipment cost per case lands under $0.40. Even at a conservative 2,000 shots per case, it stays under $0.50.
A platform system at platform pricing cannot reach that number, because the amortisation base is two orders of magnitude larger. That is arithmetic, not a product claim.
Break-even in clients, not months
| Metric | Moxi (platform) | Pico (tabletop) |
|---|---|---|
| Hardware | Hundreds of thousands | $1,250–1,300 |
| Revenue per client | $1,800–2,700 (3 sessions) | $900–2,400 (3–6 sessions) |
| Clients to cover hardware | Hundreds | 3–5 |
| Ongoing cost | Handpiece, service contract | Probes (wear item), no licence fee |
Three to five clients covering the machine is not a marketing line. It is what happens when a $1,300 console meets a $300–500 ticket.
What that does not mean: it does not mean the tabletop replaces a Moxi. It cannot do 1927 nm water absorption, so the diffuse-photodamage client still needs the other platform. What it means is that if you are choosing your first capital purchase and your intake skews toward ink and discrete pigment, the pico pays for itself before your first month of bookings closes.
Multi-colour work is the other argument. A four-wavelength pico clears ink a two-wavelength machine leaves behind, which turns “we can’t finish that sleeve” into a completed case and a referral.
Working out equipment cost per treatment for your own menu?
Tell us your client mix and we will quote the wavelength configuration that fits it — factory-direct, with operator training included.
Melasma: Where the Two Diverge Most
Melasma is the indication most often mishandled, and it is where the “which is stronger” question does the most damage.
Epidermal melasma responds to low-density, low-fluence 1927 nm. Because the energy is absorbed by water above the dermo-epidermal junction, melanocyte stimulation is limited — clinicians using Moxi report low flare risk and use it as a first-line laser for surface melasma.
Dermal or active melasma is a different animal. 755 nm at normal fluence is a flare waiting to happen. The common conservative path is 1064 nm at low fluence with large spot size — toning, not destruction — and even that gets deferred during active phases.
The order of operations matters more than the device:
- Wood’s lamp or dermatoscopic assessment to establish epidermal vs dermal vs mixed.
- Confirm the client is not in an active phase (recent sun, hormonal trigger, ongoing irritation).
- Treat only after topical prep — sunscreen, and typically tranexamic acid or hydroquinone per your protocol.
- Space sessions widely. Melasma is managed, not erased.
- Re-assess at 8–12 weeks before adding energy.
Melasma’s first-line treatment is not a laser. It is UV control and topicals. Any device you buy is the third line, and if a sales rep tells you otherwise, that is your signal to slow down.
The 12-Month Plan If You Own Both
Clinics that run both do not use them as alternatives. They use them as two positions on the same calendar.
| Month | Device | Purpose |
|---|---|---|
| March | Moxi, Level 2 | Clear winter pigment load, prep the canvas |
| April | — | Let the epidermis settle, assess |
| June | Pico 1064 nm | Residual discrete spots, tone refinement |
| August | — | Peak UV, no resurfacing |
| September | Moxi, Level 1–2 | Post-summer correction, low downtime |
| December | Pico 1064 nm or 1320 nm carbon peel | Event-season brightening |
Sequencing rules that keep you out of trouble:
- Non-ablative fractional → pico: wait two to four weeks. The epidermis needs to finish shedding before you add photoacoustic energy.
- Pico → non-ablative fractional: one to two weeks, and only if there is no lingering erythema.
- Never stack both in the same week on the same area. You will not be able to tell which device caused a reaction, and the client will not care which one it was.
Which One to Buy First
Four questions, in order.
1. What is your intake? Count the last 50 consultations. Tattoo, PMU, and discrete pigment above 30% → pico first. Diffuse dullness and maintenance above 50% → 1927 nm first.
2. Does your existing kit already cover one side? If you run CO₂ or fractional RF, you already handle texture and scarring. The wavelength gap (755 nm for green ink, 1064 nm for deep pigment) is harder to work around than an energy gap. Buy the pico.
3. What is your budget reality? Platform pricing versus $1,250 is not a close comparison. If capital is constrained, the tabletop pico starts earning in weeks. If you need the 1927 nm indication specifically, look at affordable fractional resurfacing alternatives rather than defaulting to the premium platform.
4. Can your operators run it safely? Every wavelength you add is a training obligation. 755 nm on darker skin, 1064 nm near the eye, 1927 nm at high density — each carries its own endpoint. A machine your team cannot operate conservatively is a liability, not an asset.
FAQ
Is Moxi stronger than pico?
No. They target different chromophores. Moxi’s 1927 nm is absorbed by water; pico’s 755/1064 nm is absorbed by melanin. Ranking them by strength compares two unrelated mechanisms.
Which is better for melasma?
Depends on type. Epidermal melasma responds to low-density 1927 nm. Dermal or active melasma is treated conservatively with low-fluence 1064 nm, or deferred. Assessment comes first, device second.
How much downtime does each have?
Moxi: makeup after 24 hours at low intensity; 5–7 days at Level 3. Pico: 1–3 days of pinkness for facial pigment, longer for aggressive tattoo sessions.
Can a pico laser replace a Moxi?
No. A 755/1064 system has no water-absorbing 1927 nm band, so it cannot deliver whole-epidermis renewal for diffuse photodamage. It covers a different client.
What does each machine cost a clinic?
Platform-class systems run into the hundreds of thousands. A tabletop four-wavelength pico lists at $1,250–1,300 per set. Divide by treatment volume before you compare — cost per case is the only number that matters.
The Decision Is About Your Client Mix, Not the Machine
Neither device wins. Your intake decides.
If your bookings are ink and spots, a $1,300 four-wavelength pico pays for itself in three to five clients and adds a carbon peel line to fill the gaps. If your bookings are “make me look rested,” you need the 1927 nm indication, and that is a different capital conversation.
What you should not do is buy based on a blog post that ranks lasers by “power.” That framing exists because it sells consultations. It does not help you build a menu.
Tell us your client mix and current equipment, and we will tell you which wavelength gap is costing you bookings. IVIVA LASER supplies clinical-grade picosecond and fractional platforms factory-direct, with operator training and CE/RoHS documentation for your import file.