M8 microneedling trainning course
1) Pre-treatment preparation
Skin cleansing
-
Clean the skin with deep cleansing instruments (e.g., small bubbles / hydro-type deep cleaning).
Client safety & comfort
-
Ask in advance whether the client is allergic to numbing cream.
-
Clients who are more sensitive to pain may take oral painkillers in advance (as appropriate) to relieve pain.
Numbing cream application
-
Apply numbing cream to the treatment area.
-
Use a film stick to evenly smooth/wipe the surface of the numbing cream.
-
Cover the area with clean plastic wrap/film.
-
Wait 30–45 minutes.
2) Sterilization & hygiene standards
Device and operator
-
Sterilize the instrument screen and handle.
-
Operator must wear disposable medical gloves.
Removing numbing cream
-
Use the film stick to scrape off the numbing cream (including cream under the plastic wrap).
Disinfecting the treatment site
-
Wipe the area with iodine-moistened gauze.
-
Then wipe again with saline-moistened gauze.
3) Installing the disposable operating head
-
Select the operating head based on the size of the treatment area.
-
Install the disposable operating head onto the handle.
-
On the device screen:
-
Select Face or Body
-
Select the needle number that matches the operating head
-
Enter the next interface and confirm the correct head selection
-
4) Parameter setup (Face mode)
Activation
-
Swipe the card to activate the device so parameters can be adjusted.
Adjustable parameters
-
Time: 0–60 minutes
-
RF energy (recommended): 100–118
-
Depth: choose according to the treatment area and client needs
Modes & shot mechanisms
-
Regular mode: base/neck operation uses regular mode only (no extra selection needed).
-
Single shot mechanism: press the foot pedal once → one shot, energy released once.
-
Dual shot mechanism: press the foot pedal once → two rounds, energy released twice
-
Suitable for skilled operators and clients with more serious skin laxity.
-
Saving parameter presets
-
M1–M5 are parameter storage modes.
-
Adjust parameters → click Store to save.
5) Operating technique (Face)
Starting the treatment
-
Click Start.
-
Begin from the chin.
Correct probe handling
-
Press the probe vertically against the skin.
-
Step on the foot pedal to fire.
-
After firing, retract the needle from the skin, then move to the next spot immediately.
Coverage rules
-
Overlap each adjacent pass by 1/3.
-
Reason: there may be a gap between the probe edge and the needle area, so overlap helps avoid missed spots.
-
Cover the full treatment area 1–2 times.
-
Areas needing improvement may be treated more than once.
Managing minor bleeding
-
If slight bleeding occurs, gently press with saline-soaked gauze.
6) Forehead, periocular, and nose operation
Forehead
-
Operate the forehead using the same pattern.
-
Focus more passes on areas needing improvement.
Periocular (around the eyes) & nose
-
Choose 12P operating head.
-
Lower eye area: ask the client to open eyes; treat the lower eye area carefully.
-
Avoid: eyeballs and eyebrows.
-
Upper eyelid: gently lift the eyebrows and operate along the upper eye socket.
-
Proceed with careful nose manipulation as needed.
7) Post-treatment care (Face)
Immediate recovery steps
-
Apply restorative products such as restorative essence.
Normal post-treatment reactions
-
Redness, heat, and a pinprick sensation may appear—this is described as normal.
Cooling support
-
Use an ice hammer or ice packs if needed.
Mask protocol
-
After completing the whole face, apply a biofiber mask for 20–30 minutes.
-
Remove the mask after time is up.
Final cleanup + repair
-
Clean the face with saline-moistened gauze.
-
Apply restorative products again (restorative essence / repair products).
Symmetry
-
After finishing the right side, repeat the same steps on the left side.
8) Body operation (Abdomen example)
Preparation
-
Clean the operation area.
-
If hair is excessive, shave before operation.
Numbing + disinfection
-
Apply numbing cream evenly with a film stick, cover with film, wait 30–45 minutes.
-
Scrape off numbing cream with the film stick.
-
Disinfect with iodine gauze, then wipe with saline gauze.
Body mode parameters (as stated)
-
Select Body mode and matching needle number.
-
Time: 0–60 minutes
-
Energy: 200
Technique and safety zones
-
Probe vertical to skin → foot pedal → needle launch → retract → move to next point.
-
Overlap by 1/3.
-
Avoid:
-
Ribs
-
Pelvic bone
-
Area within 2 cm of the navel
-
Body post-care
-
Apply restorative essence and/or microneedling special products.
-
Clean with saline gauze.
-
Apply repair essence and other repair products.
9) Training reminders
-
Maintain strict sterilization and single-use disposable head practice.
-
Choose needle count, depth, and energy based on the treatment area and client needs.
-
Use single vs. dual shot appropriately based on operator skill and client skin condition.
-
Follow consistent overlap and coverage to ensure uniform results.