U11 7D HIFU + RF Microneedle Machine — Two Modalities in One Unit
A tabletop platform with two handles: a 7D focused-ultrasound handle at 4 MHz with seven cartridges from 1.5 mm to 13.0 mm, and an RF microneedle handle at 1 MHz with needle depth adjustable from 0.1 to 3 mm and negative-pressure assistance. Three working modes, a 13.3-inch touchscreen, 50 W RF on a 200 W machine, 8 kg body.
Full specification table, the seven cartridge depths, the published energy and shot counts per treatment area, and the user manual download are all further down this page.
US$1,290 – US$1,690 per set · FOB Shenzhen · MOQ 1 set

What the U11 Is

The U11 is a two-modality aesthetic unit for clinics, salons and distributors. Instead of buying a HIFU machine and an RF microneedling machine separately, one 27.4 × 40.1 × 26.6 cm body carries both: a 7D focused-ultrasound handle that reaches a fixed depth per cartridge, and an RF microneedle handle that delivers radiofrequency straight into the dermis at a depth you set needle by needle.
The two handles do different jobs and are not interchangeable. The 7D handle fires ultrasound below the surface without breaking the skin — the depth is decided by which of the seven cartridges is fitted. The RF microneedle handle physically enters the skin, so the needle length, the vacuum level and the firing mode decide how much energy lands where. Operators pick the handle by treatment goal, not by preference.
Everything runs from the 13.3-inch screen: three modes (7D HIFU, gold microneedling, negative-pressure RF), single or repeated firing with a 0.5 / 1.0 / 1.5 mm step, fixed or cycle mode switching, and vacuum in four steps (off, weak, medium, strong). The interface ships in two languages and can be re-branded for OEM orders.
Technical Specifications
Every figure below is taken from the U11 user manual and the manufacturer technical sheet. Nothing on this page is estimated.
| Parameter | Specification |
|---|---|
| Model | U11 |
| Modalities | 7D focused ultrasound (HIFU) + RF microneedling, two handles |
| Working modes | 7D HIFU mode, gold microneedling mode, negative-pressure RF mode |
| 7D ultrasound handle | 4 MHz focused ultrasound output, 7 operating heads at fixed dotting depths |
| 7D cartridge depths | 1.5 / 2.0 / 3.0 / 4.5 / 6.0 / 9.0 / 13.0 mm |
| RF microneedle handle | 1 MHz RF output, controllable microneedle length 0.1–3 mm |
| Microneedle types | 10-pin, 25-pin, 64-pin, 81-pin, nano microneedle, large negative-pressure RF head, small negative-pressure RF head |
| Negative pressure | Four steps — off / weak / medium / strong |
| Trigger | Single or repeated firing; 0.5 / 1.0 / 1.5 mm step in repeated mode |
| Mode switching | Fixed or cycle |
| Display | 13.3-inch LCD touchscreen |
| RF power | 50 W |
| Total power | 200 W |
| Input power | AC 100–240 V, 50 Hz / 60 Hz |
| Interface languages | Two — English and Chinese |
| Machine size | 27.4 × 40.1 × 26.6 cm |
| Machine weight | 8 kg |
| Packaging | 48.5 × 48.5 × 31 cm, 16.2 kg |
| Stated functions | Firming, anti-aging, lifting |
| OEM / ODM | Logo and interface language customisation |
| Minimum order | 1 set |
Package figures are for the standard single-unit carton. Confirm the exact configuration, cartridge set and microneedle types on your quotation.
The Two Handles
Same body, same screen, two completely different treatments. This is the part buyers get wrong: the handles are not a light version and a strong version of the same thing.
7D HIFU handle — 4 MHz, cartridge decides the depth
RF microneedle handle — 1 MHz, needle depth 0.1–3 mm
7D ultrasound handle — no needle, fixed depth per cartridge
Four megahertz of focused ultrasound leaves the cartridge, passes through the surface and converges into a thermal point at a set depth. Because the depth is machined into the cartridge, changing treatment depth means changing the cartridge — there is no dial. The handle runs single-point or repeated firing with a 0.5, 1.0 or 1.5 mm step between points, and the operator works in either imprint or lifting mode depending on whether the goal is line work or a lift pattern.
Practical consequence: the 7D handle treats a volume at one depth per pass, so a jawline protocol and a neck protocol are different cartridges, not different settings.
RF microneedle handle — needle, depth you set, vacuum assist
The RF handle drives 1 MHz current through an insulated microneedle array. Needle length is adjustable from 0.1 to 3 mm, so the energy is released inside the dermis rather than on the surface, and the vacuum step holds the tissue against the head so the needles enter at a consistent depth. Seven head types cover different jobs: 10, 25, 64 and 81-pin arrays, a nano microneedle for surface work, and large and small negative-pressure RF heads for area work — each head is explained further down this page.
Practical consequence: this handle treats a plane at a depth you choose, which is why it is the one used for texture, pores and scarring while the 7D handle is used for lift.
Seven Cartridges, 1.5 mm to 13.0 mm
The 7D handle ships with a cartridge for each depth. The right-hand columns below are the treatment areas the manual pairs with each cartridge, and the energy band it publishes for them.

Seven 7D cartridges, each marked with its dotting depth.
| Depth | Layer reached | Areas the manual pairs it with | Published energy |
|---|---|---|---|
| 1.5 mm | Upper dermis | Around the eyes and brow bone; forehead and fine lines (paired with 3.0 mm) | Low, 0.2–0.45 J |
| 2.0 mm | Dermis | Around the eyes and brow bone — the thinnest area in the published protocol | Low, 0.2–0.45 J |
| 3.0 mm | Deep dermis | Forehead and fine lines, cheeks and mid-face, neck firming | Low to medium, 0.4–0.8 J |
| 4.5 mm | SMAS layer | Mandibular border and lower face — the core lifting area in the published protocol | Medium to high, 0.8–1.2 J |
| 6.0 mm | Subcutaneous | Upper arms and butterfly sleeves; above the knee | Medium to high, 0.8–1.2 J |
| 9.0 mm | Subcutaneous fat | Abdomen and waist, hips and thighs; upper arms | Medium to high, 0.8–1.2 J |
| 13.0 mm | Deep subcutaneous fat | Abdomen and waist, hips and thighs — the deepest body cartridge | Medium to high, 0.8–1.2 J |
Cartridges are consumables and are ordered by depth. Confirm the mix you need with the quotation — a face-only clinic and a body-focused clinic do not need the same seven.
Seven Heads for the RF Handle
One handle, seven interchangeable heads. The head — not the screen — decides how much skin the RF touches per stamp, so it is the part that has to match your treatment menu.
The RF microneedle handle and its head range — four pin arrays, the nano head, and the large and small negative-pressure heads.
Every head is a disposable: a clear body with the array on the face and a collar that seats on the handle with a push and a quarter turn. Depth is not set by the head. The needles are adjustable from 0.1 to 3 mm on the screen, so the head chooses coverage and how the array contacts the skin, while the machine chooses depth, vacuum and energy.
That split is why two clinics running identical machines can be on completely different consumables. A menu built on fine lines and upper-lip work lives on the 10 and 25-pin; a room doing cheeks, jawline and neck in volume runs 64 and 81-pin; a body protocol needs the negative-pressure chambers, because the handle has to pull up and hold a fold of tissue rather than press against a flat surface.
The nano head is the exception in the set. It is the head the manual allows for the fast sliding pass — the passage that otherwise warns a needle longer than 0.5 mm will scratch the skin during a slide explicitly excepts the microcrystalline head — and it is the head used when the aim is getting product into the skin rather than delivering RF at depth.
Heads are consumables: the manual specifies one person, one use, one disposal. The handle itself is wiped with an alcohol swab between clients, avoiding the connector interface.
10-pin array
The narrowest array of the four pin heads. Ten pins commit very little skin per stamp, so the operator can follow a line rather than carpet an area. Slower per square centimetre, and the most controllable of the set.
Typical use — fine lines, upper-lip and peri-oral lines, small zones and individual scar lines.
25-pin array
A 5 × 5 grid — the middle of the range and the head most facial work falls back on. Big enough to move at a working pace, small enough to sit flat on a cheekbone or a jaw curve without one edge lifting off.
Typical use — full-face texturing, cheeks, forehead and the nasolabial area.
64-pin array
An 8 × 8 grid, roughly two and a half times the coverage of the 25-pin per stamp. Fewer stamps to cover the same area, at the cost of precision on narrow features.
Typical use — cheeks, jawline, neck and décolletage — large flat or gently curved areas.
81-pin array
A 9 × 9 grid and the densest of the pin arrays: the highest fractional coverage per stamp in the set. Best on broad, flat surfaces — on a tight curve the outer pins can lose contact and the energy goes where the head is touching, not where it is aimed.
Typical use — body zones and broad facial areas where density matters more than precision.
Nano microneedle head
Short, ultra-fine pins instead of a depth array — a surface head. It is the one head the manual excepts from the “keep the needle at 0.5 mm or less when sliding” rule, because its pins are fine enough to glide rather than catch.
Typical use — product infusion, the fast sliding pass, superficial texture work.
Large negative-pressure RF head
The wide vacuum chamber. Suction lifts a broad fold of tissue into the head so the array engages a domed surface evenly instead of pressing flat against it. One of the two negative-pressure heads in the box.
Typical use — abdomen, thighs, upper arms, and lax facial or neck tissue.
Small negative-pressure RF head
The same principle at a narrow diameter, for places a wide chamber cannot seal — the suction has to be local or it simply draws air around the rim. The second negative-pressure head in the box.
Typical use — around the eyes, upper lip, nose side, jawline edge and the neck.
Which Head for Which Job
| Fine lines, upper lip, small zones | 10-pin |
| Full-face texture at a working pace | 25-pin |
| Cheeks, jawline and neck in volume | 64-pin |
| Body areas, maximum coverage per stamp | 81-pin |
| Product infusion and the sliding pass | Nano microneedle head |
| Loose tissue on body, neck or jawline | Large negative-pressure head |
| Eyes, upper lip, narrow contours | Small negative-pressure head |
The manual names all seven heads and publishes the vacuum and stamp settings for the handle, but it does not publish a separate energy protocol per head. The notes above describe what each array geometry is for; the parameters still come from the operator, the depth setting and the client’s response. Confirm the head mix on your quotation — consumables are ordered by type and pin count.
Three Working Modes
Two belong to the RF handle, one to the ultrasound handle. The distinction matters when a client asks what is being done to their skin.
7D HIFU mode
Focused ultrasound at 4 MHz, delivered as thermal points at the cartridge depth. No needle, no open skin. Single or repeated firing with a 0.5 / 1.0 / 1.5 mm step; imprint or lifting pattern.
4 MHz · 7 depths · no downtime expected
Gold microneedling mode
RF through a coated microneedle head, with the negative-pressure head holding the tissue steady while it works. Used where the operator wants the needle array to stay in contact across an area rather than being re-stamped point by point.
1 MHz · vacuum assist · area work
Negative-pressure RF mode
RF microneedling with vacuum in four steps — off, weak, medium, strong. Suction lifts the treatment area into the head so the needles engage the same depth across uneven surfaces.
1 MHz · needle 0.1–3 mm · vacuum 4 steps
Sliding technique — for product infusion
Needle set at 0.5 mm or less, a fast pass of 0.1–0.2 s, vacuum at 0, moving in one direction along the skin texture. The manual notes this pass does not require numbing — except on sensitive areas, where it does — and that the needle must stay short or it will scratch the skin during the slide. On sensitive areas the path changes to a zigzag or spiral.
Stamp technique — for depth
Needle inserted 0.5–3 mm, speed 0.4–0.5, vacuum 1–2, with RF increased in step with insertion depth. Numbing is used. The manual positions this as the technique for thinner skin and for texture, pores and scarring, because the RF acts in the dermis instead of overheating the epidermis.
These are the manufacturer’s published technique notes, not a training course. Operators should be trained on the device before treating clients.
Published 7D HIFU Settings by Treatment Area
Most listings stop at “7 depths”. The U11 manual goes further and publishes a starting point for each area — cartridge, energy band, shot count and the safety line that goes with it. Reproduced here so a buyer can see the whole protocol before paying.
| Treatment area | Probe | Energy | Shots (reference) | Manufacturer safety note |
|---|---|---|---|---|
| Around the eyes and brow bone | 1.5 / 2.0 mm | Low, 0.2–0.45 J | 100–150 | Bony support area above the brow only. Not on the eyelids or above the eyeballs. |
| Forehead and fine lines | 1.5 / 3.0 mm | Low to medium, 0.4–0.8 J | 150–250 | Avoid the glabella, the inner eyebrow and 2 cm in front of the hairline. Work parallel to the lines. |
| Cheeks and mid-face | 3.0 mm | Medium, 0.6–1.0 J | 300–500 | Start at the nose side, move up toward the ear; avoid the highest point of the cheekbone. |
| Mandibular border and lower face | 4.5 / 3.0 mm | Medium to high, 0.8–1.2 J | 200–300 | Core lifting area. Close to the lower jaw edge, chin toward earlobe. |
| Neck (firming) | 3.0 mm | Low to medium, 0.4–0.7 J | 150–250 | Adam’s apple and thyroid are absolute no-go areas. Platysma only; low energy rather than high. |
| Upper arms and butterfly sleeves | 6.0 / 9.0 mm | Medium to high, 0.8–1.2 J | 200–300 | Armpit toward elbow, close to the loose skin. Avoid high energy over bone and nerve. |
| Abdomen and waist | 9.0 / 13.0 mm | Medium to high, 0.8–1.2 J | 200–300 | Work in drawn zones. Avoid the navel, groin and rib edges. |
| Hips and thighs | 9.0 / 13.0 mm | Medium to high, 0.8–1.2 J | 200–300 | Dots vertically or at 45 degrees for sagging and loose skin. |
| Above the knee | 6.0 mm | Medium, 0.6–1.0 J | 200–300 | Not too deep, and keep clear of the kneecap. |
Shot counts are the manual’s reference ranges, not fixed prescriptions. Energy should start low on first treatment and on sensitive skin, and be raised against the client’s tolerance and feedback during the session.
See It Running
Three published videos: a short explanation of how the two modalities fit together, a walkaround of the hardware, and the 7D HIFU handle in use on a face.
How it works — the two handles, the seven depths and the RF microneedle setup, in under a minute.
Product showcase — body, screen, handles and cartridge set.
7D HIFU handle — clinical demonstration on the face and jawline.
What an Operator Actually Does
Six steps from switching on to cleaning down. The interface is one screen, not a menu tree — mode, depth, vacuum, step and energy are all visible at once.
Welcome screen: the RF microneedle handle on the left, the 7D HIFU handle on the right.
Set up and self-test
Place the unit on a stable surface, connect the handle and power, switch on and let the self-test finish.
Prepare the site
Clean and dry the skin. For 7D work apply a thick, even layer of ultrasound gel; for RF work fit a new disposable microneedle.
Choose the mode
7D HIFU, gold microneedling or negative-pressure RF, from the 13.3-inch screen.
Set the parameters
Cartridge for 7D; needle length, vacuum step, firing step and energy for RF. Start low on first treatment and on sensitive skin.
Treat and watch the skin
Work the pattern for the area. If the client reports sharp pain, stop and reduce energy rather than pushing through.
Clean down
Stop, clean the probe and remove the gel or the used microneedle. Log the settings used for the next session.
What Ships With the Machine
The complete kit as rendered below: the body, both handles, the seven-depth cartridge set and the microneedle heads.

Machine, both handles, the 7D cartridges on the left and the RF microneedle heads on the right.
One tabletop body with the 13.3-inch screen, two side hangers and the handle connectors on the rear panel
4 MHz focused-ultrasound handle
1 MHz RF handle with adjustable needle length 0.1–3 mm
Seven cartridges, one per depth: 1.5 / 2.0 / 3.0 / 4.5 / 6.0 / 9.0 / 13.0 mm
Packing list: six microneedle probes plus one large and one small negative-pressure head. Types set by order — 10, 25, 64 or 81-pin, nano, large or small negative-pressure RF head
Plug to destination
English manual covering specification, installation, interface and treatment parameters
Cartridges and microneedle heads are consumables. The exact mix in your box is set on the order — tell us the treatment mix you plan to run and we will quote the cartridge set to match.
Body, Connectors and Bench Footprint
An 8 kg tabletop unit at 27.4 × 40.1 × 26.6 cm — it sits on a treatment trolley or a bench, not on the floor. The rear panel carries the power switch, the two handle connectors and the power inlet, so nothing plugs into the front.
Perforated shell with the light points showing through.
Rear connectors and the illuminated power switch.
Rear panel: power switch, handle connectors, power inlet, both handles parked.
Three-quarter view: angled screen, both handles on their hangers.
Who Buys It
Skin clinics and salons
One bench unit covering both lift protocols and texture protocols, with the shot counts and energy bands already documented for the operator.
Body and contouring rooms
The 6.0, 9.0 and 13.0 mm cartridges reach subcutaneous depth, so the same machine runs abdomen, waist, hips, thighs and upper arms.
Distributors and OEM buyers
Two-language interface and logo customisation, minimum order one set, consumables supplied by depth and pin count for resale.
Areas the manual pairs with the machine: around the eyes and brow, forehead and fine lines, cheeks and mid-face, jawline and lower face, neck, upper arms, abdomen and waist, hips and thighs, above the knee.
Questions Buyers Ask
Straight answers, with the numbers taken from the manual rather than from a brochure.
What is the difference between the two handles?
Are cartridges and microneedles consumables?
Which microneedle head should I order?
How deep can it actually treat?
Does the RF microneedle handle need numbing?
What settings does the manual recommend for a face treatment?
Can both modalities be used in the same session?
What power and space does it need?
Can we put our own brand on it?
Documents and Video
The English user manual covers the specification table, installation, the interface, the technique notes and the full parameter table for nine treatment areas.
Manual is the standard English edition. Other language editions and OEM-branded manuals are produced to order.
Related Reading
HIFU Machines
The wider HIFU range — 2D, 3D, 4D and 7D platforms, and how the cartridges differ between them.
RF Microneedling Machines
Fractional RF microneedling machines compared on needle depth, pin count and vacuum.
4D vs 7D HIFU
What the 7D designation actually changes against 3D and 4D HIFU, and where it stops mattering.
Ultra 360 RF + Ultrasound
The other two-in-one option in our range — monopolar RF and ultrasound in one body.
Price, Lead Time and Cartridge Mix
US$1,290 – US$1,690 per set, FOB Shenzhen. The band covers the standard two-handle configuration; where your order lands inside it depends on the cartridge depths and microneedle types you take.
Tell us how many sets, which country they are going to, and what treatments you plan to run. We confirm the exact figure together with the cartridge depths and microneedle types that actually match your menu, and the lead time at the same time.
Professional aesthetic equipment. For use by trained operators only. Not intended to diagnose or treat disease.
