U11 7D HIFU + RF Microneedle Machine | 2-in-1 HIFU & RF Microneedling

U11 7D HIFU + RF Microneedle Machine — Two Modalities in One Unit

A tabletop platform with two handles: a 7D focused-ultrasound handle at 4 MHz with seven cartridges from 1.5 mm to 13.0 mm, and an RF microneedle handle at 1 MHz with needle depth adjustable from 0.1 to 3 mm and negative-pressure assistance. Three working modes, a 13.3-inch touchscreen, 50 W RF on a 200 W machine, 8 kg body.

Full specification table, the seven cartridge depths, the published energy and shot counts per treatment area, and the user manual download are all further down this page.

7D HIFU · 4 MHzRF Microneedle · 1 MHz7 Depths 1.5–13.0 mmNeedle 0.1–3 mm7 RF Head TypesNegative-Pressure + Gold Modes13.3-inch Screen

US$1,290 – US$1,690 per set · FOB Shenzhen · MOQ 1 set

Request price and lead timeWatch it running

U11 7D HIFU and RF microneedle machine in front view, showing the 13.3-inch touchscreen, the 7D HIFU handle on the left hanger and the RF microneedle handle on the right

What the U11 Is

Side view of the U11 machine showing the reclined 13.3-inch screen, the black body and a handle resting in its side hanger

The U11 is a two-modality aesthetic unit for clinics, salons and distributors. Instead of buying a HIFU machine and an RF microneedling machine separately, one 27.4 × 40.1 × 26.6 cm body carries both: a 7D focused-ultrasound handle that reaches a fixed depth per cartridge, and an RF microneedle handle that delivers radiofrequency straight into the dermis at a depth you set needle by needle.

The two handles do different jobs and are not interchangeable. The 7D handle fires ultrasound below the surface without breaking the skin — the depth is decided by which of the seven cartridges is fitted. The RF microneedle handle physically enters the skin, so the needle length, the vacuum level and the firing mode decide how much energy lands where. Operators pick the handle by treatment goal, not by preference.

Everything runs from the 13.3-inch screen: three modes (7D HIFU, gold microneedling, negative-pressure RF), single or repeated firing with a 0.5 / 1.0 / 1.5 mm step, fixed or cycle mode switching, and vacuum in four steps (off, weak, medium, strong). The interface ships in two languages and can be re-branded for OEM orders.

2Handles in one body
77D cartridge depths
0.1–3 mmRF needle depth
8 kgMachine weight

Technical Specifications

Every figure below is taken from the U11 user manual and the manufacturer technical sheet. Nothing on this page is estimated.

Parameter Specification
Model U11
Modalities 7D focused ultrasound (HIFU) + RF microneedling, two handles
Working modes 7D HIFU mode, gold microneedling mode, negative-pressure RF mode
7D ultrasound handle 4 MHz focused ultrasound output, 7 operating heads at fixed dotting depths
7D cartridge depths 1.5 / 2.0 / 3.0 / 4.5 / 6.0 / 9.0 / 13.0 mm
RF microneedle handle 1 MHz RF output, controllable microneedle length 0.1–3 mm
Microneedle types 10-pin, 25-pin, 64-pin, 81-pin, nano microneedle, large negative-pressure RF head, small negative-pressure RF head
Negative pressure Four steps — off / weak / medium / strong
Trigger Single or repeated firing; 0.5 / 1.0 / 1.5 mm step in repeated mode
Mode switching Fixed or cycle
Display 13.3-inch LCD touchscreen
RF power 50 W
Total power 200 W
Input power AC 100–240 V, 50 Hz / 60 Hz
Interface languages Two — English and Chinese
Machine size 27.4 × 40.1 × 26.6 cm
Machine weight 8 kg
Packaging 48.5 × 48.5 × 31 cm, 16.2 kg
Stated functions Firming, anti-aging, lifting
OEM / ODM Logo and interface language customisation
Minimum order 1 set

Package figures are for the standard single-unit carton. Confirm the exact configuration, cartridge set and microneedle types on your quotation.

The Two Handles

Same body, same screen, two completely different treatments. This is the part buyers get wrong: the handles are not a light version and a strong version of the same thing.

U11 7D HIFU handle with a cartridge fitted, held in a gloved hand against a white background

7D HIFU handle — 4 MHz, cartridge decides the depth

U11 RF microneedle handle with a clear nano microneedle tip fitted, held in a gloved hand against a white background

RF microneedle handle — 1 MHz, needle depth 0.1–3 mm

7D ultrasound handle — no needle, fixed depth per cartridge

Four megahertz of focused ultrasound leaves the cartridge, passes through the surface and converges into a thermal point at a set depth. Because the depth is machined into the cartridge, changing treatment depth means changing the cartridge — there is no dial. The handle runs single-point or repeated firing with a 0.5, 1.0 or 1.5 mm step between points, and the operator works in either imprint or lifting mode depending on whether the goal is line work or a lift pattern.

Practical consequence: the 7D handle treats a volume at one depth per pass, so a jawline protocol and a neck protocol are different cartridges, not different settings.

RF microneedle handle — needle, depth you set, vacuum assist

The RF handle drives 1 MHz current through an insulated microneedle array. Needle length is adjustable from 0.1 to 3 mm, so the energy is released inside the dermis rather than on the surface, and the vacuum step holds the tissue against the head so the needles enter at a consistent depth. Seven head types cover different jobs: 10, 25, 64 and 81-pin arrays, a nano microneedle for surface work, and large and small negative-pressure RF heads for area work — each head is explained further down this page.

Practical consequence: this handle treats a plane at a depth you choose, which is why it is the one used for texture, pores and scarring while the 7D handle is used for lift.

Seven Cartridges, 1.5 mm to 13.0 mm

The 7D handle ships with a cartridge for each depth. The right-hand columns below are the treatment areas the manual pairs with each cartridge, and the energy band it publishes for them.

Seven U11 7D HIFU cartridges laid out in two rows on a white surface, each marked with its treatment depth from 1.5 mm to 13.0 mm

Seven 7D cartridges, each marked with its dotting depth.

Depth Layer reached Areas the manual pairs it with Published energy
1.5 mm Upper dermis Around the eyes and brow bone; forehead and fine lines (paired with 3.0 mm) Low, 0.2–0.45 J
2.0 mm Dermis Around the eyes and brow bone — the thinnest area in the published protocol Low, 0.2–0.45 J
3.0 mm Deep dermis Forehead and fine lines, cheeks and mid-face, neck firming Low to medium, 0.4–0.8 J
4.5 mm SMAS layer Mandibular border and lower face — the core lifting area in the published protocol Medium to high, 0.8–1.2 J
6.0 mm Subcutaneous Upper arms and butterfly sleeves; above the knee Medium to high, 0.8–1.2 J
9.0 mm Subcutaneous fat Abdomen and waist, hips and thighs; upper arms Medium to high, 0.8–1.2 J
13.0 mm Deep subcutaneous fat Abdomen and waist, hips and thighs — the deepest body cartridge Medium to high, 0.8–1.2 J

Cartridges are consumables and are ordered by depth. Confirm the mix you need with the quotation — a face-only clinic and a body-focused clinic do not need the same seven.

Seven Heads for the RF Handle

One handle, seven interchangeable heads. The head — not the screen — decides how much skin the RF touches per stamp, so it is the part that has to match your treatment menu.

U11 RF microneedle handle on the left and the seven microneedle heads it accepts on the right: 10-pin, 25-pin, 64-pin and 81-pin arrays, a nano microneedle head, and large and small negative-pressure RF heads

The RF microneedle handle and its head range — four pin arrays, the nano head, and the large and small negative-pressure heads.

Every head is a disposable: a clear body with the array on the face and a collar that seats on the handle with a push and a quarter turn. Depth is not set by the head. The needles are adjustable from 0.1 to 3 mm on the screen, so the head chooses coverage and how the array contacts the skin, while the machine chooses depth, vacuum and energy.

That split is why two clinics running identical machines can be on completely different consumables. A menu built on fine lines and upper-lip work lives on the 10 and 25-pin; a room doing cheeks, jawline and neck in volume runs 64 and 81-pin; a body protocol needs the negative-pressure chambers, because the handle has to pull up and hold a fold of tissue rather than press against a flat surface.

The nano head is the exception in the set. It is the head the manual allows for the fast sliding pass — the passage that otherwise warns a needle longer than 0.5 mm will scratch the skin during a slide explicitly excepts the microcrystalline head — and it is the head used when the aim is getting product into the skin rather than delivering RF at depth.

Heads are consumables: the manual specifies one person, one use, one disposal. The handle itself is wiped with an alcohol swab between clients, avoiding the connector interface.

10 PINS

10-pin array

The narrowest array of the four pin heads. Ten pins commit very little skin per stamp, so the operator can follow a line rather than carpet an area. Slower per square centimetre, and the most controllable of the set.

Typical use — fine lines, upper-lip and peri-oral lines, small zones and individual scar lines.

25 PINS

25-pin array

A 5 × 5 grid — the middle of the range and the head most facial work falls back on. Big enough to move at a working pace, small enough to sit flat on a cheekbone or a jaw curve without one edge lifting off.

Typical use — full-face texturing, cheeks, forehead and the nasolabial area.

64 PINS

64-pin array

An 8 × 8 grid, roughly two and a half times the coverage of the 25-pin per stamp. Fewer stamps to cover the same area, at the cost of precision on narrow features.

Typical use — cheeks, jawline, neck and décolletage — large flat or gently curved areas.

81 PINS

81-pin array

A 9 × 9 grid and the densest of the pin arrays: the highest fractional coverage per stamp in the set. Best on broad, flat surfaces — on a tight curve the outer pins can lose contact and the energy goes where the head is touching, not where it is aimed.

Typical use — body zones and broad facial areas where density matters more than precision.

NANO

Nano microneedle head

Short, ultra-fine pins instead of a depth array — a surface head. It is the one head the manual excepts from the “keep the needle at 0.5 mm or less when sliding” rule, because its pins are fine enough to glide rather than catch.

Typical use — product infusion, the fast sliding pass, superficial texture work.

LARGE NEG. PRESSURE

Large negative-pressure RF head

The wide vacuum chamber. Suction lifts a broad fold of tissue into the head so the array engages a domed surface evenly instead of pressing flat against it. One of the two negative-pressure heads in the box.

Typical use — abdomen, thighs, upper arms, and lax facial or neck tissue.

SMALL NEG. PRESSURE

Small negative-pressure RF head

The same principle at a narrow diameter, for places a wide chamber cannot seal — the suction has to be local or it simply draws air around the rim. The second negative-pressure head in the box.

Typical use — around the eyes, upper lip, nose side, jawline edge and the neck.

Which Head for Which Job

Fine lines, upper lip, small zones 10-pin
Full-face texture at a working pace 25-pin
Cheeks, jawline and neck in volume 64-pin
Body areas, maximum coverage per stamp 81-pin
Product infusion and the sliding pass Nano microneedle head
Loose tissue on body, neck or jawline Large negative-pressure head
Eyes, upper lip, narrow contours Small negative-pressure head

The manual names all seven heads and publishes the vacuum and stamp settings for the handle, but it does not publish a separate energy protocol per head. The notes above describe what each array geometry is for; the parameters still come from the operator, the depth setting and the client’s response. Confirm the head mix on your quotation — consumables are ordered by type and pin count.

Three Working Modes

Two belong to the RF handle, one to the ultrasound handle. The distinction matters when a client asks what is being done to their skin.

01

7D HIFU mode

Focused ultrasound at 4 MHz, delivered as thermal points at the cartridge depth. No needle, no open skin. Single or repeated firing with a 0.5 / 1.0 / 1.5 mm step; imprint or lifting pattern.

4 MHz · 7 depths · no downtime expected

02

Gold microneedling mode

RF through a coated microneedle head, with the negative-pressure head holding the tissue steady while it works. Used where the operator wants the needle array to stay in contact across an area rather than being re-stamped point by point.

1 MHz · vacuum assist · area work

03

Negative-pressure RF mode

RF microneedling with vacuum in four steps — off, weak, medium, strong. Suction lifts the treatment area into the head so the needles engage the same depth across uneven surfaces.

1 MHz · needle 0.1–3 mm · vacuum 4 steps

Sliding technique — for product infusion

Needle set at 0.5 mm or less, a fast pass of 0.1–0.2 s, vacuum at 0, moving in one direction along the skin texture. The manual notes this pass does not require numbing — except on sensitive areas, where it does — and that the needle must stay short or it will scratch the skin during the slide. On sensitive areas the path changes to a zigzag or spiral.

Stamp technique — for depth

Needle inserted 0.5–3 mm, speed 0.4–0.5, vacuum 1–2, with RF increased in step with insertion depth. Numbing is used. The manual positions this as the technique for thinner skin and for texture, pores and scarring, because the RF acts in the dermis instead of overheating the epidermis.

These are the manufacturer’s published technique notes, not a training course. Operators should be trained on the device before treating clients.

Published 7D HIFU Settings by Treatment Area

Most listings stop at “7 depths”. The U11 manual goes further and publishes a starting point for each area — cartridge, energy band, shot count and the safety line that goes with it. Reproduced here so a buyer can see the whole protocol before paying.

Treatment area Probe Energy Shots (reference) Manufacturer safety note
Around the eyes and brow bone 1.5 / 2.0 mm Low, 0.2–0.45 J 100–150 Bony support area above the brow only. Not on the eyelids or above the eyeballs.
Forehead and fine lines 1.5 / 3.0 mm Low to medium, 0.4–0.8 J 150–250 Avoid the glabella, the inner eyebrow and 2 cm in front of the hairline. Work parallel to the lines.
Cheeks and mid-face 3.0 mm Medium, 0.6–1.0 J 300–500 Start at the nose side, move up toward the ear; avoid the highest point of the cheekbone.
Mandibular border and lower face 4.5 / 3.0 mm Medium to high, 0.8–1.2 J 200–300 Core lifting area. Close to the lower jaw edge, chin toward earlobe.
Neck (firming) 3.0 mm Low to medium, 0.4–0.7 J 150–250 Adam’s apple and thyroid are absolute no-go areas. Platysma only; low energy rather than high.
Upper arms and butterfly sleeves 6.0 / 9.0 mm Medium to high, 0.8–1.2 J 200–300 Armpit toward elbow, close to the loose skin. Avoid high energy over bone and nerve.
Abdomen and waist 9.0 / 13.0 mm Medium to high, 0.8–1.2 J 200–300 Work in drawn zones. Avoid the navel, groin and rib edges.
Hips and thighs 9.0 / 13.0 mm Medium to high, 0.8–1.2 J 200–300 Dots vertically or at 45 degrees for sagging and loose skin.
Above the knee 6.0 mm Medium, 0.6–1.0 J 200–300 Not too deep, and keep clear of the kneecap.

Shot counts are the manual’s reference ranges, not fixed prescriptions. Energy should start low on first treatment and on sensitive skin, and be raised against the client’s tolerance and feedback during the session.

See It Running

Three published videos: a short explanation of how the two modalities fit together, a walkaround of the hardware, and the 7D HIFU handle in use on a face.

How it works — the two handles, the seven depths and the RF microneedle setup, in under a minute.

Product showcase — body, screen, handles and cartridge set.

7D HIFU handle — clinical demonstration on the face and jawline.

More videos on our YouTube channel

What an Operator Actually Does

Six steps from switching on to cleaning down. The interface is one screen, not a menu tree — mode, depth, vacuum, step and energy are all visible at once.

U11 welcome screen showing the RF microneedle handle illustration on the left and the 7D HIFU handle illustration on the right of a black interface

Welcome screen: the RF microneedle handle on the left, the 7D HIFU handle on the right.

STEP 01

Set up and self-test

Place the unit on a stable surface, connect the handle and power, switch on and let the self-test finish.

STEP 02

Prepare the site

Clean and dry the skin. For 7D work apply a thick, even layer of ultrasound gel; for RF work fit a new disposable microneedle.

STEP 03

Choose the mode

7D HIFU, gold microneedling or negative-pressure RF, from the 13.3-inch screen.

STEP 04

Set the parameters

Cartridge for 7D; needle length, vacuum step, firing step and energy for RF. Start low on first treatment and on sensitive skin.

STEP 05

Treat and watch the skin

Work the pattern for the area. If the client reports sharp pain, stop and reduce energy rather than pushing through.

STEP 06

Clean down

Stop, clean the probe and remove the gel or the used microneedle. Log the settings used for the next session.

What Ships With the Machine

The complete kit as rendered below: the body, both handles, the seven-depth cartridge set and the microneedle heads.

Studio render of the complete U11 kit: the machine with both handles in their hangers, the 7D HIFU cartridges laid out on the left and the RF microneedle heads on the right

Machine, both handles, the 7D cartridges on the left and the RF microneedle heads on the right.

U11 main unit
One tabletop body with the 13.3-inch screen, two side hangers and the handle connectors on the rear panel
7D HIFU handle
4 MHz focused-ultrasound handle
RF microneedle handle
1 MHz RF handle with adjustable needle length 0.1–3 mm
7D cartridge set
Seven cartridges, one per depth: 1.5 / 2.0 / 3.0 / 4.5 / 6.0 / 9.0 / 13.0 mm
Microneedle heads
Packing list: six microneedle probes plus one large and one small negative-pressure head. Types set by order — 10, 25, 64 or 81-pin, nano, large or small negative-pressure RF head
Power cord
Plug to destination
User manual
English manual covering specification, installation, interface and treatment parameters

Cartridges and microneedle heads are consumables. The exact mix in your box is set on the order — tell us the treatment mix you plan to run and we will quote the cartridge set to match.

Body, Connectors and Bench Footprint

An 8 kg tabletop unit at 27.4 × 40.1 × 26.6 cm — it sits on a treatment trolley or a bench, not on the floor. The rear panel carries the power switch, the two handle connectors and the power inlet, so nothing plugs into the front.

Close-up of the U11 body edge showing the perforated panel with blue light points showing through the black shell

Perforated shell with the light points showing through.

Close-up of the U11 rear connectors and the illuminated power switch below the perforated light strip

Rear connectors and the illuminated power switch.

Rear panel of the U11 machine with the power switch, the two blue handle connectors and the power inlet, both handles parked in their holders

Rear panel: power switch, handle connectors, power inlet, both handles parked.

Three-quarter studio render of the U11 machine showing the angled screen, the perforated body and both handles in their hangers

Three-quarter view: angled screen, both handles on their hangers.

Who Buys It

Skin clinics and salons

One bench unit covering both lift protocols and texture protocols, with the shot counts and energy bands already documented for the operator.

Body and contouring rooms

The 6.0, 9.0 and 13.0 mm cartridges reach subcutaneous depth, so the same machine runs abdomen, waist, hips, thighs and upper arms.

Distributors and OEM buyers

Two-language interface and logo customisation, minimum order one set, consumables supplied by depth and pin count for resale.

Areas the manual pairs with the machine: around the eyes and brow, forehead and fine lines, cheeks and mid-face, jawline and lower face, neck, upper arms, abdomen and waist, hips and thighs, above the knee.

Questions Buyers Ask

Straight answers, with the numbers taken from the manual rather than from a brochure.

What is the difference between the two handles?
The 7D handle fires 4 MHz focused ultrasound from a cartridge and never breaks the skin — the cartridge sets the depth (1.5 to 13.0 mm). The RF microneedle handle physically enters the skin and delivers 1 MHz RF at a needle depth you set from 0.1 to 3 mm, with vacuum assist. The 7D handle works a volume at one depth; the RF handle works a plane at a depth you choose.
Are cartridges and microneedles consumables?
Yes. 7D cartridges are ordered by depth and the microneedle heads by pin count and type, and both are replaced as they are used. Tell us the treatment mix you plan to run and the cartridge and needle set is quoted to match, rather than shipping a fixed box that does not fit your menu.
Which microneedle head should I order?
Match the head to your treatment menu, not to the machine. Line work, upper lip and small zones: 10 or 25-pin. Cheeks, jawline and neck in volume: 64 or 81-pin. Product infusion and the sliding pass: the nano head. Loose tissue on the body, neck or jawline: the large negative-pressure head; eyes, upper lip and narrow contours: the small one. Depth is set on the screen either way, so the head is a coverage decision, not a depth decision. Send us your menu and we quote the mix.
How deep can it actually treat?
The thinnest areas, around the eyes and brow, use the 1.5 mm and 2.0 mm cartridges. The 3.0 mm reaches the deep dermis for forehead, cheeks and neck, the 4.5 mm reaches the SMAS at the jawline, and the 6.0, 9.0 and 13.0 mm cartridges reach subcutaneous depth for arms, abdomen, waist, hips and thighs. On the RF side the needle is adjustable from 0.1 to 3 mm.
Does the RF microneedle handle need numbing?
It depends which technique is used. The sliding pass, with the needle at 0.5 mm or less and vacuum off, does not require numbing except on sensitive areas. The stamp technique at 0.5 to 3 mm insertion does use numbing. Both techniques are documented in the manual with their speed and vacuum settings.
What settings does the manual recommend for a face treatment?
For the jawline it publishes the 4.5 mm and 3.0 mm cartridges at 0.8 to 1.2 J and 200 to 300 shots, and for the cheeks the 3.0 mm at 0.6 to 1.0 J and 300 to 500 shots. The eye area is the 1.5 or 2.0 mm cartridge at 0.2 to 0.45 J, bony brow only. The full table for nine areas is on this page.
Can both modalities be used in the same session?
The machine supports both, and both are on the same screen, so nothing stops an operator running them back to back. Whether to combine them, in what order and with what interval is a clinical decision for the treating practitioner — the manual documents each modality separately rather than prescribing a combined protocol.
What power and space does it need?
AC 100 to 240 V at 50 or 60 Hz, 200 W total, 50 W of that on the RF side. The body is 27.4 × 40.1 × 26.6 cm and weighs 8 kg, so it runs from a standard outlet on a bench or trolley. It ships in a 48.5 × 48.5 × 31 cm carton at 16.2 kg.
Can we put our own brand on it?
Yes. Logo and interface language are customisable, the standard interface ships in English and Chinese, and the minimum order is one set. Machine colour and packaging can be discussed with the quotation.

Documents and Video

The English user manual covers the specification table, installation, the interface, the technique notes and the full parameter table for nine treatment areas.

Manual is the standard English edition. Other language editions and OEM-branded manuals are produced to order.

Related Reading

HIFU Machines

The wider HIFU range — 2D, 3D, 4D and 7D platforms, and how the cartridges differ between them.

Read more →

RF Microneedling Machines

Fractional RF microneedling machines compared on needle depth, pin count and vacuum.

Read more →

4D vs 7D HIFU

What the 7D designation actually changes against 3D and 4D HIFU, and where it stops mattering.

Read more →

HIFU Technology Guide

4D, 7D, 12D, 22D and 25D explained without the marketing layer.

Read more →

Ultra 360 RF + Ultrasound

The other two-in-one option in our range — monopolar RF and ultrasound in one body.

Read more →

RF Microneedling vs CO2 Laser

Downtime, indication and cost per session, side by side.

Read more →

Price, Lead Time and Cartridge Mix

US$1,290 – US$1,690 per set, FOB Shenzhen. The band covers the standard two-handle configuration; where your order lands inside it depends on the cartridge depths and microneedle types you take.

Tell us how many sets, which country they are going to, and what treatments you plan to run. We confirm the exact figure together with the cartridge depths and microneedle types that actually match your menu, and the lead time at the same time.

Name *
Fill out this field
Email *
Please enter a valid email address.
Message *
Fill out this field
Country *
Fill out this field
Phone
Fill out this field
Whatsapp
Fill out this field

Professional aesthetic equipment. For use by trained operators only. Not intended to diagnose or treat disease.